The only dual-cure sold by dose.

Our single-dose Encore D/C MiniMix kit contains 36 cartridges. Each cartridge has two mixing nozzles and our exclusive needletip. Our product is dual-cure, for fast light-activation. Plus, the smaller size and ease of use will save you valuable chair time and reduce patient stress. Available with fluoride release and in natural and contrast shades.
•Light-activate for 40 seconds for complete cure
•Needletip allows delivery of material to bottom of a post hole
•MiniMix technology virtually eliminates waste
•Non-slumping formula so there is no need to use a matrix
•Cuts like dentin to reduce ditching
•Contains fluoride
•Radiopaque

 

Q: Does Encore D/C MiniMix contain fluoride?

A: Yes

Q: Do you sell MiniMix mixing nozzles separately?

A: Yes, we do.

Q: How many doses does one Encore D/C MiniMix provide?

A: On average two. We provide two mixing nozzles for each MiniMix.

 

How to Use Encore D/C AutoMix

1
Isolate the tooth to be prepared. We recommend the use of a rubber dam or cotton rolls.
2
Remove all existing restorations and decay from the tooth. At this time you may place any pins or posts if necessary.
3
Acid etch the entire preparation for 20 seconds using (32% to 40%) phosphoric acid. We recommend the use of Centrix Onyx 40% phosphoric etch gel.
4
Rinse with a water spray for 30 seconds and lightly air dry. 
The enamel of the preparation should have a frosted appearance.
5
Place bonding system of your choice onto the preparation, according to the manufacture's instructions. When placing the primer, be sure that all of the solvent has been evaporated and the preparation has a glossy appearance. Before light curing, the bonding agent should be thinned with a light air spray.
6
Select the desired shade of ENCORE D/C AUTOMIX core buildup material and place the appropriate cartridge into the Type S25 Applicator Gun.
Natural Shade (A2) for use under ceramic crowns.
Contrast Shade (blue) to distinguish core material from tooth structure.
7
Remove the cap from the cartridge and attach a new mixing nozzle. If desired, an Intra Oral tip (Centrix Access II Intraoral Needletip REF 290025) may be snapped into the open end of the mixing nozzle and inserted into the open root canal.
8
The cap should remain on the cartridge until ready for use! When using a cartridge for the first time, express a "pea" size amount of material and discard!

APPLICATION

Place the Intra-Oral tip at the base of the preparation and inject from the bottom up. Keep tip embedded in the material to avoid air entrapment. Fill as needed to complete the restoration.

IF USING A MATRIX BAND

1
To facilitate placement, a matrix band may be placed around the prepared tooth.
2
Place the mixing tip directly into the preparation and squeeze the trigger of the applicator gun to express the paste.
3
If a matrix band was used, test with an explorer to insure that material has set prior to removal. Once set, cut and finish the preparation, using water-cooled diamonds or burs.

IF USING A PREFABRICATED CROWN FORM

When using a prefabricated crown form, place the mixing tip directly into the crown form and squeeze the trigger of the cartridge to express the paste. Place the loaded crown form onto the prepared tooth and hold into place until the paste is fully set.

CHEMICAL CURE

ENCORED/C AUTOMIX core build up paste has a 1:30 minute working time. The material may be manipulated using a composite instrument. A flat-ended interproximal carver (IPC) is recommended. ENCORED/C AUTOMIX core build up paste has a 5 minute chemical cure set time (no light curing).

LIGHT CURING

ENCORED/C AUTOMIX core build up paste may be light cured with a standard dental halogen lamp for 40 seconds (4mm max.). A thin layer (<2mm) will need only 20 second light cure. If a matrix band was used, test with an explorer to insure that material has set prior to its removal. Once set, cut and finish the preparation, water-cooled diamonds or burs.

PRECAUTIONS

How to Use Encore D/C MiniMix

1
Isolate the tooth to be prepared. We recommend the use of a rubber dam or cotton rolls.
2
Remove all existing restorations and decay from the tooth. At this time you may place any pins or posts if necessary.
3
Acid etch the entire preparation for 20 seconds using (32% to 40%) phosphoric acid. We recommend the use of Centrix Onyx 40% phosphoric etch gel.
4
Rinse with a water spray for 30 seconds and lightly air dry. The enamel of the preparation should have a frosted appearance.
5
Place bonding system of your choice onto the preparation, according to the manufacturer's instructions. Do not use one bottle bonding systems. When placing the primer, be sure that all of the solvent has been evaporated and the preparation has a glossy appearance. Before light curing, the bonding agent should be thinned with a light air spray.
6
Build up core

IF USING A MATRIX BAND

1
To facilitate placement, a matrix band may be placed around the prepared tooth.
2
Place the mixing tip directly into the preparation and squeeze the trigger of the applicator gun to express the paste.
3
If a matrix band was used, test with an explorer to insure that material has set prior to removal. Once set, cut and finish the preparation, using water-cooled diamonds or burs.

IF USING A PREFABRICATED CROWN FORM

1
Place the mixing tip directly into the crown form and squeeze the trigger of the cartridge to express the paste.
2
Place the loaded crown form onto the prepared tooth and hold into place until the paste is fully set.

Encore D/C MiniMix core buildup paste has a 1:30 minute working time. The material may be manipulated using a composite instrument. A flat-ended interproximal carver (IPC) is recommended. Light activate with a standard dental halogen lamp or LED curing unit for 40 seconds (per 4mm layer). A thinner layer (<2mm) will need only a 20 second light exposure. To complete the chemical cure activation, wait 5 minutes before cutting and finishing the prep. If a matrix band was used, test with an explorer to insure that material has set prior to its removal. Once set, cut and finish the preparation, using water-cooled diamonds or burs.

PRECAUTIONS